VLAN Overview
This chapter shows you how to configure 802.1Q tagged and port-based VLANs.
The type of screen you see here depends on the VLAN Type you selected in the SYSTEM > Switch Setup screen.
Introduction to IEEE 802.1Q Tagged VLANs
A tagged VLAN uses an explicit tag (VLAN ID) in the MAC header to identify the VLAN membership of a frame across bridges they are not confined to the switch on which they were created. The VLANs can be created statically by hand or dynamically through GVRP. The VLAN ID associates a frame with a specific VLAN and provides the information that switches need to process the frame across the network. A tagged frame is 4 bytes longer than an untagged frame and contains 2 bytes of TPID (Tag Protocol Identifier, residing within the type or length field of the Ethernet frame) and 2 bytes of TCI (Tag Control Information, starts after the source address field of the Ethernet frame).
The CFI (Canonical Format Indicator) is a single-bit flag, always set to zero for Ethernet switches. If a frame received at an Ethernet port has a CFI set to 1, then that frame should not be forwarded as it is to an untagged port. The remaining twelve bits define the VLAN ID, giving a possible maximum number of 4096 VLANs. Note that user priority and VLAN ID are independent of each other. A frame with VID (VLAN Identifier) of null (0) is called a priority frame, meaning that only the priority level is significant and the default VID of the ingress port is given as the VID of the frame. Of the 4096 possible VIDs, a VID of 0 is used to identify priority frames and value 4095 (FFF) is reserved, so the maximum possible VLAN configurations are 4094.
TPID
16 Bits
User Priority
3 Bits
CFI
1 Bit
VLAN ID
12 Bits
Each port on the Switch is capable of passing tagged or untagged frames. To forward a frame from an 802.1Q VLAN-aware switch to an 802.1Q VLAN-unaware switch, the Switch first decides where to forward the frame and then strips off the VLAN tag. To forward a frame from an 802.1Q VLAN-unaware switch to an 802.1Q VLAN-aware switch, the Switch first decides where to forward the frame, and then inserts a VLAN tag reflecting the ingress port's default VID. The default PVID is VLAN 1 for all ports, but this can be changed.
A broadcast frame (or a multicast frame for a multicast group that is known by the system) is duplicated only on ports that are members of the VID (except the ingress port itself), thus confining the broadcast to a specific domain.
Automatic VLAN Registration
GARP and GVRP are the protocols used to automatically register VLAN membership across switches.
GARP
GARP (Generic Attribute Registration Protocol) allows network switches to register and de-register attribute values with other GARP participants within a bridged LAN. GARP is a protocol that provides a generic mechanism for protocols that serve a more specific application, for example, GVRP.
GARP Timers
Switches join VLANs by making a declaration. A declaration is made by issuing a Join message using GARP. Declarations are withdrawn by issuing a Leave message. A Leave All message terminates all registrations. GARP timers set declaration timeout values.
GVRP
GVRP (GARP VLAN Registration Protocol) is a registration protocol that defines a way for switches to register necessary VLAN members on ports across the network. Enable this function to permit VLAN groups beyond the local Switch.
Please refer to the following table for common IEEE 802.1Q VLAN terminology.
IEEE 802.1Q VLAN Terminology 
VLAN Parameter
Term
Description
VLAN Type
Permanent VLAN
This is a static VLAN created manually.
Dynamic VLAN
This is a VLAN configured by a GVRP registration or de-registration process.
VLAN Administrative Control
Registration Fixed
Fixed registration ports are permanent VLAN members.
Registration Forbidden
Ports with registration forbidden are forbidden to join the specified VLAN.
Normal Registration
Ports dynamically join a VLAN using GVRP.
VLAN Tag Control
Tagged
Ports belonging to the specified VLAN tag all outgoing frames transmitted.
Untagged
Ports belonging to the specified VLAN do not tag all outgoing frames transmitted.
VLAN Port
Port VID
This is the VLAN ID assigned to untagged frames that this port received.
Acceptable Frame Type
You may choose to accept both tagged and untagged incoming frames, just tagged incoming frames or just untagged incoming frames on a port.
Ingress filtering
If set, the Switch discards incoming frames for VLANs that do not have this port as a member.
Port VLAN Trunking
Enable VLAN Trunking on a port to allow frames belonging to unknown VLAN groups to pass through that port. This is useful if you want to set up VLAN groups on end devices without having to configure the same VLAN groups on intermediary devices.
VLAN Status
Use this screen to view and search all VLAN groups.
The following table describes the labels in this screen.
SWITCHING > VLAN > VLAN Status 
label
description
VLAN Search by VID
Enter (an) existing VLAN ID numbers (use a comma (,) to separate individual VLANs or a hyphen (-) to indicate a range of VLANs. For example, “3,4” or “3-9”) and click Search to display only the specified VLANs in the list below.
Leave this field blank and click Search to display all VLANs configured on the Switch.
The Number of VLAN
This is the number of VLANs configured on the Switch.
The Number of Search Results
This is the number of VLANs that match the searching criteria and display in the list below.
This field displays only when you use the Search button to look for certain VLANs.
Index
This is the VLAN index number. Click an index number to view more VLAN details.
VID
This is the VLAN identification number that was configured in the corresponding VLAN configuration screen.
Name
This fields shows the descriptive name of the VLAN.
Tagged Port
This field shows the tagged ports that are participating in the VLAN.
Untagged Port
This field shows the untagged ports that are participating in the VLAN.
Elapsed Time
This field shows how long it has been since a normal VLAN was registered or a static VLAN was set up.
Status
This field shows how this VLAN was added to the Switch.
Static: added as a permanent entry.
VLAN Details
Use this screen to view detailed port settings and status of the VLAN group. Click an index number in the VLAN Status screen to display VLAN details.
The following table describes the labels in this screen.
SWITCHING > VLAN > VLAN Status > VLAN Status Details 
label
description
VID
This is the VLAN identification number that was configured in the corresponding VLAN configuration screen.
Elapsed Time
This field shows how long it has been since a normal VLAN was registered or a static VLAN was set up.
Status
This field shows how this VLAN was added to the Switch.
Dynamic: using GVRP
Static: added as a permanent entry
Voice: manually added as a Voice VLAN
MVR: added through multicast VLAN registration
MAC-based: manually added as MAC-based VLAN
Port Number
This section displays the ports that are participating in a VLAN. A tagged port is marked as T, an untagged port is marked as U and ports not participating in a VLAN are marked as ““.
Static VLAN
Use this screen to view and configure a static VLAN for the Switch.
The following table describes the related labels in this screen.
SWITCHING > VLAN > VLAN Setup > Static VLAN 
label
Description
VID
This field displays the ID number of the VLAN group.
Active
This field indicates whether the VLAN settings are enabled or disabled.
Name
This field displays the descriptive name for this VLAN group.
 
Select an entry’s checkbox to select a specific entry. Otherwise, select the checkbox in the table heading row to select all entries.
Add/Edit
Click Add/Edit to add a new static VLAN or edit a selected one.
Delete
Click Delete to remove the selected static VLAN.
Add/Edit a Static VLAN
Use this screen to configure a static VLAN for the Switch. Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN > VLAN Setup > Static VLAN screen to display this screen.
The following table describes the related labels in this screen.
SWITCHING > VLAN > VLAN Setup > Static VLAN > Add/Edit 
label
Description
Active
Enable the switch button to activate the VLAN settings.
Name
Enter a descriptive name for the VLAN group for identification purposes. This name consists of up to 64 printable ASCII characters. The string should not contain [ ? ], [ | ], [ ' ], [ " ], or [ , ].
VLAN Group ID
Enter the VLAN ID for this static entry; the valid range is between 1 and 4094.
*Do NOT add a VLAN ID that has been used in the SWITCHING > VLAN > Voice VLAN Setup.
Port
The port number identifies the port you are configuring.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set the common settings and then make adjustments on a port-by-port basis.
*Changes in this row are copied to all the ports as soon as you make them.
Control
Select Normal for the port to dynamically join this VLAN group using GVRP. This is the default selection.
Select Fixed for the port to be a permanent member of this VLAN group.
Select Forbidden if you want to prohibit the port from joining this VLAN group.
Tagging
Select Tx Tagging if you want the port to tag all outgoing frames transmitted with this VLAN Group ID.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Clear
Click Clear to clear the fields to the factory defaults.
Cancel
Click Cancel to not save the configuration you make and return to the last screen.
VLAN Port Setup
Use this screen to configure the static VLAN (IEEE 802.1Q) settings on a port.
The following table describes the labels in this screen.
SWITCHING > VLAN > VLAN Setup > VLAN Port Setup 
label
description
Port
This field displays the port number.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set the common settings and then make adjustments on a port-by-port basis.
*Changes in this row are copied to all the ports as soon as you make them.
Ingress Check
If this checkbox is selected, the Switch discards incoming frames on a port for VLANs that do not include this port in its member set.
Clear this checkbox to disable ingress filtering.
PVID
A PVID (Port VLAN ID) is a tag that adds to incoming untagged frames received on a port so that the frames are forwarded to the VLAN group that the tag defines.
Enter a number between 1and 4094 as the port VLAN ID.
Acceptable Frame Type
Specify the type of frames allowed on a port. Choices are All, Tag Only and Untag Only.
Select All from the drop-down list box to accept all untagged or tagged frames on this port. This is the default setting.
Select Tag Only to accept only tagged frames on this port. All untagged frames will be dropped.
Select Untag Only to accept only untagged frames on this port. All tagged frames will be dropped.
VLAN Trunking
Enable VLAN Trunking on ports connected to other switches or routers (but not ports directly connected to end users) to allow frames belonging to unknown VLAN groups to pass through the Switch.
Isolation
Select this to allows this port to communicate only with the CPU management port and the ports on which the isolation feature is NOT enabled.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
GVRP
Use this screen to configure GVRP settings on a port.
The following table describes the labels in this screen.
SWITCHING > VLAN > VLAN Setup > GVRP 
label
description
GVRP
GVRP (GARP VLAN Registration Protocol) is a registration protocol that defines a way for switches to register necessary VLAN members on ports across the network.
Enable the switch button to permit VLAN groups beyond the local Switch.
Port
This field displays the port number.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set the common settings and then make adjustments on a port-by-port basis.
*Changes in this row are copied to all the ports as soon as you make them.
GVRP
Select this checkbox to allow GVRP on this port.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Subnet Based VLAN
Subnet based VLANs allow you to group traffic into logical VLANs based on the source IP subnet you specify. When a frame is received on a port, the Switch checks if a tag is added already and the IP subnet it came from. The untagged packets from the same IP subnet are then placed in the same subnet based VLAN. One advantage of using subnet based VLANs is that priority can be assigned to traffic from the same IP subnet.
*Subnet based VLAN applies to un-tagged packets and is applicable only when you use IEEE 802.1Q tagged VLAN.
The following table describes the labels in this screen.
SWITCHING > VLAN > Subnet Based VLAN Setup > Subnet Based VLAN 
label
description
Active
Enable the switch button to activate this subnet based VLANs on the Switch.
DHCP-VLAN Override
When DHCP snooping is enabled DHCP clients can renew their IP address through the DHCP VLAN or through another DHCP server on the subnet based VLAN.
Enable the switch button to force the DHCP clients in this IP subnet to obtain their IP addresses through the DHCP VLAN.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Index
This is the index number identifying this subnet based VLAN.
Active
This field shows whether the subnet based VLAN is active or not.
Name
This field shows the name the subnet based VLAN.
IP
This field shows the IP address of the subnet for this subnet based VLAN.
Mask-Bits
This field shows the subnet mask in bit number format for this subnet based VLAN.
VID
This field shows the VLAN ID of the frames which belong to this subnet based VLAN.
Priority
This field shows the priority which is assigned to frames belonging to this subnet based VLAN.
 
Select an entry’s checkbox to select a specific entry. Otherwise, select the checkbox in the table heading row to select all entries.
Add/Edit
Click Add/Edit to add a new entry or edit a selected one.
Delete
Click Delete to remove the selected entry.
Add/Edit Subnet Based VLAN
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN > Subnet Based VLAN Setup > Subnet Based VLAN screen to display this screen.
The following table describes the labels in this screen.
SWITCHING > VLAN > Subnet Based VLAN Setup > Subnet Based VLAN > Add/Edit 
label
description
Active
Enable the switch button to activate the IP subnet VLAN you are creating or editing.
Name
Enter up to 32 alphanumeric characters to identify this subnet based VLAN. The string should not contain [ ? ], [ | ], [ ' ], [ " ], or [ , ].
IP
Enter the IP address of the subnet for which you want to configure this subnet based VLAN.
Mask-Bits
Enter the bit number of the subnet mask. To find the bit number, convert the subnet mask to binary format and add all the 1’s together. Take “255.255.255.0” for example. 255 converts to eight 1s in binary. There are three 255s, so add three eights together and you get the bit number (24).
VLAN
Enter the ID of a VLAN with which the untagged frames from the IP subnet specified in this subnet based VLAN are tagged. This must be an existing VLAN which you defined in the SWITCHING > VLAN > VLAN Setup > Static VLAN screen.
Priority
Select the priority level that the Switch assigns to frames belonging to this VLAN.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Clear
Click Clear to clear the fields to the factory defaults.
Cancel
Click Cancel to not save the configuration you make and return to the last screen.
Protocol Based VLAN
Protocol based VLANs allow you to group traffic into logical VLANs based on the protocol you specify. When an upstream frame is received on a port (configured for a protocol based VLAN), the Switch checks if a tag is added already and its protocol. The untagged packets of the same protocol are then placed in the same protocol based VLAN. One advantage of using protocol based VLANs is that priority can be assigned to traffic of the same protocol.
*Protocol-based VLAN applies to un-tagged packets and is applicable only when you use IEEE 802.1Q tagged VLAN.
The following table describes the labels in this screen.
SWITCHING > VLAN > Protocol Based VLAN Setup > Protocol Based VLAN 
label
description
Index
This is the index number identifying this protocol based VLAN. Click any of these numbers to edit an existing protocol based VLAN.
Active
This field shows whether the protocol based VLAN is active or not.
Port
This field shows which port belongs to this protocol based VLAN.
Name
This field shows the name of the protocol based VLAN.
Ethernet-type
This field shows which Ethernet protocol is part of this protocol based VLAN.
VID
This field shows the VLAN ID of the port.
Priority
This field shows the priority which is assigned to frames belonging to this protocol based VLAN.
 
Select an entry’s checkbox to select a specific entry. Otherwise, select the checkbox in the table heading row to select all entries.
Add/Edit
Click Add/Edit to add a new entry or edit a selected one.
Delete
Click Delete to remove the selected entry.
Add/Edit a Protocol Based VLAN
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN > Protocol Based VLAN Setup > Protocol Based VLAN screen to display this configuration screen.
The following table describes the labels in this screen.
SWITCHING > VLAN > Protocol Based VLAN Setup > Protocol Based VLAN Setup > Add/Edit 
label
description
Active
Enable the switch button to activate this protocol based VLAN.
Port
Type a port to be included in this protocol based VLAN.
This port must belong to a static VLAN in order to participate in a protocol based VLAN.
Name
Enter up to 32 alphanumeric characters to identify this protocol based VLAN. The string should not contain [ ? ], [ | ], [ ' ], [ " ], or [ , ].
Ethernet-type
Use the drop down list box to select a predefined protocol to be included in this protocol based VLAN or select Other and type the protocol number in hexadecimal notation. For example the IP protocol in hexadecimal notation is 0800, and Novell IPX protocol is 8137.
*Protocols in the hexadecimal number range of 0x0000 to 0x05ff are not allowed to be used for protocol based VLANs.
VLAN
Enter the ID of a VLAN to which the port belongs. This must be an existing VLAN which you defined in the SWITCHING > VLAN > VLAN Setup > Static VLAN screen.
Priority
Select the priority level that the Switch will assign to frames belonging to this VLAN.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Clear
Click Clear to clear the fields to the factory defaults.
Cancel
Click Cancel to not save the configuration you make and return to the last screen.
Voice VLAN
Voice VLAN is a VLAN that is specifically allocated for voice traffic. It ensures that the sound quality of an IP phone is preserved from deteriorating when the data traffic on the Switch ports is high. It groups the voice traffic with defined priority into an assigned VLAN which enables the separation of voice and data traffic coming onto the Switch port.
The Switch can determine whether a received packet is
an untagged voice packet when the incoming port is a fixed port for voice VLAN.
a tagged voice packet when the incoming port and VLAN tag belongs to a voice VLAN.
It then checks the source packet’s MAC address against an OUI list. If a match is found, the packet is considered as a voice packet.
You can set priority level to the Voice VLAN and add MAC address of IP phones from specific manufacturers by using its ID from the Organizationally Unique Identifiers (OUI).
The following table describes the fields in the above screen.
SWITCHING > VLAN > Voice VLAN Setup > Voice VLAN Setup 
label
description
Voice VLAN Global Setup
Voice VLAN
Click the second radio button if you want to enable the Voice VLAN feature. Enter a VLAN ID number that is associated with the Voice VLAN.
Click the Disable radio button if you do not want to enable the Voice VLAN feature.
Priority
Select the priority level of the voice traffic from 0 to 7. Default setting is 5. The higher the numeric value you assign, the higher the priority for this voice traffic.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this section afresh.
Voice VLAN OUI Setup
Index
This field displays the index number of the Voice VLAN.
OUI Address
This field displays the OUI address of the Voice VLAN.
OUI Mask
This field displays the OUI mask address of the Voice VLAN.
Description
This field displays the description of the Voice VLAN with OUI address.
 
Select an entry’s checkbox to select a specific entry. Otherwise, select the checkbox in the table heading row to select all entries.
Add/Edit
Click Add/Edit to add a new entry or edit a selected one.
Delete
Click Delete to remove the selected entry.
Add/Edit a Voice VLAN
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN > Voice VLAN Setup > Voice VLAN Setup screen to display the configuration screen.
The following table describes the fields in the above screen.
SWITCHING > VLAN > Voice VLAN Setup > Voice VLAN Setup > Add/Edit 
label
description
OUI Address
Enter the IP phone manufacturer’s OUI MAC address. The first 3 bytes is the manufacturer identifier, the last 3 bytes is a unique station ID.
OUI Mask
Enter the mask for the specified IP phone manufacturer’s OUI MAC address to determine which bits a packet’s MAC address should match.
Enter “f” for each bit of the specified MAC address that the traffic’s MAC address should match. Enter “0” for the bits of the matched traffic’s MAC address, which can be of any hexadecimal characters. For example, if you set the MAC address to 00:13:49:00:00:00 and the mask to ff:ff:ff:00:00:00, a packet with a MAC address of 00:13:49:12:34:56 matches this criteria.
Description
Enter a description up to 32 printable ASCII characters except [ ? ], [ | ], [ ' ], or [ " ] for the Voice VLAN device. For example: Siemens.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Clear
Click Clear to clear the fields to the factory defaults.
Cancel
Click Cancel to not save the configuration you make and return to the last screen.
MAC Based VLAN
The MAC-based VLAN feature assigns incoming untagged packets to a VLAN and classifies the traffic based on the source MAC address of the packet. When untagged packets arrive at the Switch, the source MAC address of the packet is looked up in a MAC to VLAN mapping table. If an entry is found, the corresponding VLAN ID is assigned to the packet. The assigned VLAN ID is verified against the VLAN table. If the VLAN is valid, ingress processing on the packet continues; otherwise, the packet is dropped.
This feature allows users to change ports without having to reconfigure the VLAN. You can assign priority to the MAC-based VLAN and define a MAC to VLAN mapping table by entering a specified source MAC address in the MAC-based VLAN setup screen. You can also delete a MAC-based VLAN entry in the same screen.
The following table describes the fields in the above screen.
SWITCHING > VLAN > MAC Based VLAN Setup > MAC Based VLAN 
label
description
Index
This field displays the index number of the MAC-based VLAN entry.
Name
This field displays the name of the MAC-based VLAN entry.
MAC Address
This field displays the source MAC address that is bind to the MAC-based VLAN entry.
VID
This field displays the VLAN ID of the MAC-based VLAN entry.
Priority
This field displays the priority level which is assigned to frames belonging to this MAC-based VLAN entity.
 
Select an entry’s checkbox to select a specific entry. Otherwise, select the checkbox in the table heading row to select all entries.
Add/Edit
Click Add/Edit to add a new entry or edit a selected one.
Delete
Click Delete to remove the selected entry.
Add/Edit a MAC Based VLAN
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN > MAC Based VLAN Setup > MAC Based VLAN screen to see this screen.
The following table describes the fields in the above screen.
SWITCHING > VLAN > MAC Based VLAN Setup > MAC Based VLAN > Add/Edit 
label
description
Name
Enter a name up to 32 alphanumeric characters except [ ? ], [ | ], [ ' ], [ " ], or [ , ] for the MAC-based VLAN entry.
MAC Address
Enter a MAC address that is bind to the MAC-based VLAN entry. This is the source MAC address of the data packet that is looked up when untagged packets arrive at the Switch.
VID
Enter an ID (from 1 to 4094) for the VLAN that is associated with the MAC-based VLAN entry.
Priority
Enter a priority (0 to 7) that the Switch assigns to frames belonging to this VLAN. The higher the numeric value you assign, the higher the priority for this MAC-based VLAN entry.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Clear
Click Clear to clear the fields to the factory defaults.
Cancel
Click Cancel to not save the configuration you make and return to the last screen.
Vendor ID Based VLAN
The Vendor ID based VLAN feature assigns incoming untagged packets to a VLAN and classifies the traffic based on the source MAC address of the packet. When untagged packets arrive at the switch, the source MAC address of the packet is looked up in a Vendor ID to VLAN mapping table. If an entry is found, the corresponding VLAN ID is assigned to the packet. The assigned VLAN ID is verified against the VLAN table. If the VLAN is valid, ingress processing on the packet continues; otherwise, the packet is dropped.
This feature allows users to change ports without having to reconfigure the VLAN. You can assign a 802.1p priority to the vendor ID based VLAN and define a vendor ID to VLAN mapping table by entering a specified source MAC address and mask in the vendor ID based VLAN setup screen. You can also delete a vendor ID based VLAN entry in the same screen.
For every vendor ID based VLAN rule you set, you can specify a weight number to define the rule’s priority level. As rules are processed one after the other, stating a priority order will let you choose which rule has to be applied first and which second.
The following table describes the fields in the above screen.
SWITCHING > VLAN > Vendor ID Based VLAN Setup > Vendor ID Based VLAN 
label
description
Index
This field displays the index number of the vendor ID based VLAN entry.
Name
This field displays the name of the vendor ID based VLAN entry.
MAC Address
This field displays the source MAC address that is bind to the vendor ID based VLAN entry.
Mask
This field displays the mask for the source MAC address that is bind to the vendor ID based VLAN entry.
VID
This field displays the VLAN ID of the vendor ID based VLAN entry.
Priority
This field displays the priority level which is assigned to frames belonging to this vendor ID based VLAN.
Weight
This field displays the weight of the vendor ID based VLAN entry.
 
Select an entry’s checkbox to select a specific entry. Otherwise, select the checkbox in the table heading row to select all entries.
Add/Edit
Click Add/Edit to add a new entry or edit a selected one.
Delete
Click Delete to remove the selected entry.
Add/Edit a Vendor ID Based VLAN
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN > Vendor ID Based VLAN > Vendor ID Based VLAN Setup to see this screen.
The following table describes the fields in the above screen.
SWITCHING > VLAN > Vendor ID Based VLAN Setup > Vendor ID Based VLAN > Add/Edit 
label
description
Name
Enter a name up to 32 alphanumeric characters except [ ? ], [ | ], [ ' ], or [ " ] for the vendor ID based VLAN entry.
MAC Address
Enter a MAC address that is bind to the vendor ID-based VLAN entry. This is the source MAC address of the data packet that is looked up when untagged packets arrive at the Switch.
Mask
Enter the mask for the specified source MAC address to determine which bits a packet’s MAC address should match.
Enter “f” for each bit of the specified MAC address that the traffic’s MAC address should match. Enter “0” for the bits of the matched traffic’s MAC address, which can be of any hexadecimal characters. For example, if you set the MAC address to 00:13:49:00:00:00 and the mask to ff:ff:ff:00:00:00, a packet with a MAC address of 00:13:49:12:34:56 matches this criteria.
VID
Enter an ID (from 1 to 4094) for the VLAN that is associated with the vendor ID based VLAN entry.
Priority
Select the priority level that the Switch assigns to frames belonging to this VLAN. The higher the numeric value you assign, the higher the priority for this vendor ID based VLAN entry.
Weight
Enter a number between 0 and 255 to specify the rule’s weight. This is to decide the priority in which the rule is applied. The higher the number, the higher the rule’s priority.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Clear
Click Clear to clear the fields to the factory defaults.
Cancel
Click Cancel to not save the configuration you make and return to the last screen.
Port-Based VLAN Setup
Port-based VLANs are VLANs where the packet forwarding decision is based on the destination MAC address and its associated port.
Port-based VLANs require allowed outgoing ports to be defined for each port. Therefore, if you wish to allow two subscriber ports to talk to each other, for example, between conference rooms in a hotel, you must define the egress (an egress port is an outgoing port, that is, a port through which a data packet leaves) for both ports.
Port-based VLANs are specific only to the Switch on which they were created.
*When you activate port-based VLAN, the Switch uses a default VLAN ID of 1. You cannot change it.
*In screens (such as SYSTEM > IP Setup > IP Setup and SWITCHING > Static MAC Filtering > Static MAC Filtering) that require a VID, you must enter 1 as the VID.
The CPU management port forms a VLAN with all Ethernet ports.
Configure a Port-Based VLAN
The following table describes the labels in this screen.
SWITCHING > VLAN > Port Based VLAN Setup 
label
Description
Setting Wizard
Choose Current configuration to display the Switch’s current port-based VLAN configuration.
Choose All connected or Port isolation wizard to quickly set up a port-based VLAN according to the below descriptions.
All connected means all ports can communicate with each other, that is, there are no virtual LANs. All incoming and outgoing ports are selected. This option is the most flexible but also the least secure.
Port isolation means that each port can only communicate with the CPU management port and cannot communicate with each other. All incoming ports are selected while only the CPU outgoing port is selected. This option is the most limiting but also the most secure.
After selecting the setting wizard, you can customize the port settings. Click on the ports to add or delete incoming or outgoing ports. The configuration will be saved only after you click Apply at the bottom of the screen.
Incoming
These are the ingress ports; an ingress port is an incoming port, that is, a port through which a data packet enters. If you wish to allow two subscriber ports to talk to each other, you must define the ingress port for both ports. The numbers in the top row denote the incoming port for the corresponding port listed on the left (its outgoing port). CPU refers to the Switch management port. By default it forms a VLAN with all Ethernet ports. If it does not form a VLAN with a particular port then the Switch cannot be managed from that port.
Outgoing
These are the egress ports; an egress port is an outgoing port, that is, a port through which a data packet leaves. If you wish to allow two subscriber ports to talk to each other, you must define the egress port for both ports. CPU refers to the Switch management port. By default it forms a VLAN with all Ethernet ports. If it does not form a VLAN with a particular port then the Switch cannot be managed from that port.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
VLAN Isolation Overview
VLAN Isolation allows you to do port isolation within a VLAN in a simple way. You specify which ports in a VLAN (VLAN 123) is not isolated by adding it to the promiscuous port (PP) list. The Switch automatically adds other ports in this VLAN (VLAN 123) to the isolated port (IP) list and blocks traffic between the isolated ports (IP). A promiscuous port (PP) can communicate with any port in the same VLAN (VLAN 123). An isolated port (IP) can communicate with the promiscuous ports (PP) only.
*You can have up to one VLAN Isolation rule for each VLAN.
*Make sure you keep at least one port in the promiscuous port list for a VLAN with VLAN Isolation enabled. Otherwise, this VLAN is blocked from the whole network.
VLAN Isolation
The following table describes the labels in this screen.
SWITCHING > VLAN Isolation > VLAN Isolation
label
description
Index
This is the index number of the rule.
Active
This shows whether this rule is activated or not.
Name
This is the descriptive name for this rule.
VLAN ID
This is the VLAN to which this rule is applied.
Promiscuous Ports
This shows the ports that can communicate with any ports in the same VLAN.
 
Select an entry’s checkbox to select a specific entry. Otherwise, select the checkbox in the table heading row to select all entries.
Add/Edit
Click Add/Edit to add a new entry or edit a selected one.
Delete
Click Delete to remove the selected entries.
Add/Edit a VLAN Isolation Rule
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN Isolation > VLAN Isolation screen to display this screen.
The following table describes the labels in this screen.
SWITCHING > VLAN Isolation > VLAN Isolation > Add/Edit 
label
description
Active
Enable the switch button to enable VLAN Isolation in a VLAN.
Name
Enter a descriptive name (up to 32 printable ASCII characters except [ ? ], [ | ], [ ' ], [ " ], or [ , ]) for identification purposes.
VLAN ID
Enter a VLAN ID from 1 to 4094. This is the VLAN to which this rule applies.
Promiscuous Ports
Enter the number of the ports that can communicate with any ports in the same VLAN. Other ports belonging to this VLAN will be added to the isolation list and can only send and receive traffic from the ports you specify here.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Clear
Click Clear to clear the fields to the factory defaults.
Cancel
Click Cancel to not save the configuration you make and return to the last screen.